{"id":1691,"date":"2026-08-10T01:11:47","date_gmt":"2026-08-10T01:11:47","guid":{"rendered":"https:\/\/www.packtests.com\/?post_type=product&#038;p=1691"},"modified":"2026-08-10T01:11:47","modified_gmt":"2026-08-10T01:11:47","slug":"manual-carbonation-tester","status":"publish","type":"product","link":"https:\/\/www.packtests.com\/et\/product\/manual-carbonation-tester\/","title":{"rendered":"CLRT-02 Manual Carbonation Tester"},"content":{"rendered":"<p class=\"wp-block-paragraph\">The <strong>Manual Carbonation Tester<\/strong> provides a reliable and cost-effective solution for measuring dissolved carbon dioxide levels in beverage containers. Designed for quality control laboratories, beverage manufacturers, and R&amp;D facilities, this tester determines carbonation levels by measuring internal pressure and beverage temperature after sample preparation. By following a <strong>standard carbonation test method<\/strong> based on pressure-temperature relationships, the instrument helps engineers evaluate carbonation consistency, detect CO\u2082 loss, and maintain beverage quality.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Carbonation plays a critical role in beverage taste, mouthfeel, shelf stability, and consumer acceptance. Whether testing carbonated soft drinks, beer, sparkling water, energy drinks, or fermented beverages, accurate CO\u2082 measurement allows manufacturers to control filling processes, optimize formulations, and ensure product performance throughout the supply chain. The CLRT-02 Manual Carbonation Tester combines simple operation with precise measurement capability, making it suitable for laboratories requiring dependable <strong>carbon dioxide loss testing for beverage container<\/strong> applications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Is a Manual Carbonation Tester?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>Manual Carbonation Tester<\/strong> is a laboratory instrument used to determine the amount of dissolved CO\u2082 in carbonated beverages by measuring container pressure and sample temperature. Unlike fully automated carbonation analyzers, manual carbonation testers provide a straightforward testing workflow that allows operators to perform accurate measurements with minimal complexity.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The testing principle is based on the relationship between dissolved carbon dioxide, temperature, and pressure inside a sealed beverage container. When a beverage reaches equilibrium after agitation, the measured pressure value can be compared with carbonation reference tables to calculate the CO\u2082 volume.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The CLRT-02 Manual Carbonation Tester is designed for applications where reliable carbonation measurement is required without the cost and maintenance requirements of automated systems.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why Carbonation Testing Is Important for Beverage Quality Control<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Carbon dioxide directly influences beverage characteristics, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Taste and sensory experience:<\/strong> Proper carbonation creates the desired refreshing sensation and flavor balance.<\/li>\n\n\n\n<li><strong>Product consistency:<\/strong> Maintaining stable CO\u2082 levels ensures every production batch meets specifications.<\/li>\n\n\n\n<li><strong>Packaging performance:<\/strong> Excessive internal pressure can affect container integrity, while insufficient carbonation may reduce product quality.<\/li>\n\n\n\n<li><strong>Shelf-life evaluation:<\/strong> Monitoring CO\u2082 retention helps identify carbonation loss during storage and transportation.<\/li>\n\n\n\n<li><strong>Production optimization:<\/strong> Testing data supports filling adjustments, formulation improvements, and process control.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">For beverage manufacturers, carbonation testing is not only a quality inspection step but also an important tool for maintaining brand reputation and customer satisfaction.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ASTM F1115 Carbonation Test Method and CO\u2082 Loss Evaluation<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>ASTM F1115 standard test method<\/strong> provides guidance for determining CO\u2082 loss from beverage containers. It focuses on evaluating the change in carbonation level caused by factors such as container design, sealing performance, storage conditions, and transportation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The CLRT-02 supports testing procedures related to ASTM F1115 by allowing operators to measure:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Parameeter<\/th><th class=\"has-text-align-center\" data-align=\"center\">Eesm\u00e4rk<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Internal container pressure<\/td><td class=\"has-text-align-center\" data-align=\"center\">Determines carbonation pressure after stabilization<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Beverage temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\">Provides reference conditions for CO\u2082 calculation<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">CO\u2082 volume<\/td><td class=\"has-text-align-center\" data-align=\"center\">Evaluates carbonation level and potential CO\u2082 loss<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Although carbonation performance depends on multiple factors, pressure and temperature measurement provide essential data for understanding beverage carbonation behavior.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Testing Principle of Manual Carbonation Measurement<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The working principle of a Manual Carbonation Tester involves three key factors:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Pressure measurement<\/strong><br>The sealed beverage container is pierced, allowing the tester to measure internal gas pressure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Temperature measurement<\/strong><br>The beverage temperature is recorded because CO\u2082 solubility changes with temperature.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3. Carbonation calculation<\/strong><br>The measured pressure and temperature values are compared with carbonation tables to determine dissolved CO\u2082 volume.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This method provides a practical approach for laboratories that need repeatable carbonation testing without complicated instrumentation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How to Perform a Manual Carbonation Test<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The CLRT-02 follows a simple six-step testing workflow:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Pierce the Beverage Container<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The operator uses the hardened quenching piercing head to penetrate the bottle or container cap. The durable design ensures reliable puncturing while minimizing leakage.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Release Excess Pressure<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The vent valve is opened to safely release unstable gas pressure from the container.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Stabilize the Sample<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">After pressure release, the valve is closed to isolate the sample and prepare it for measurement.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. Agitate the Beverage<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The container is manually shaken for approximately 40 seconds. This step allows dissolved CO\u2082 to reach equilibrium between the liquid and gas phases.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">5. Measure Pressure and Temperature<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The stabilized pressure is recorded from the precision gauge, while the beverage temperature is measured for carbonation calculation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">6. Calculate CO\u2082 Volume<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The recorded pressure and temperature values are compared with carbonation reference tables to determine the final carbonation level.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This manual workflow provides laboratory users with direct control over each testing stage and improves understanding of carbonation behavior.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Key Features of CLRT-02 Manual Carbonation Tester<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The CLRT-02 is designed for beverage laboratories requiring accurate and practical carbonation measurement.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">High-Precision Pressure Measurement<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The instrument uses a pressure gauge with:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Measurement range: <strong>0\u20131 MPa<\/strong><\/li>\n\n\n\n<li>Resolution: <strong>0.0001 MPa<\/strong><\/li>\n\n\n\n<li>Multiple units: MPa, psi, bar<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The high-resolution display helps operators obtain repeatable pressure readings for carbonation evaluation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Durable Quenching Piercing Head<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The hardened piercing head provides:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Reliable bottle penetration<\/li>\n\n\n\n<li>Long service life<\/li>\n\n\n\n<li>Reduced leakage during testing<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">This design improves operational stability during frequent laboratory testing.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Anti-Leak Structure<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The sealed valve and gasket assembly minimize sample loss and maintain measurement accuracy during testing.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Flexible Sample Compatibility<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The adjustable sample height supports beverage containers up to <strong>350 mm<\/strong>, with optional extensions available for different container sizes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Simple Manual Operation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The manual workflow reduces equipment complexity while providing reliable carbonation data for daily quality control applications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Applications of Carbonation Testing Equipment<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A Manual Carbonation Tester is widely used across beverage-related industries.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Beverage Production Quality Control<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Manufacturers use carbonation testing equipment to verify CO\u2082 levels after filling and packaging processes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00fc\u00fcpilised rakendused on j\u00e4rgmised:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Soft drink production<\/li>\n\n\n\n<li>Beer quality inspection<\/li>\n\n\n\n<li>Sparkling water testing<\/li>\n\n\n\n<li>Energy drink evaluation<\/li>\n\n\n\n<li>Fermented beverage analysis<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Research and Development<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">R&amp;D teams use carbonation measurement during:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Formula development<\/li>\n\n\n\n<li>Packaging selection<\/li>\n\n\n\n<li>Shelf-life studies<\/li>\n\n\n\n<li>Protsessi optimeerimine<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Laboratory Testing Services<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Independent laboratories and educational institutions can use manual carbonation testers for beverage analysis and teaching applications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Applicable Beverage Materials and Containers<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The CLRT-02 Manual Carbonation Tester is suitable for various carbonated beverage samples, including:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Material \/ Sample<\/th><th class=\"has-text-align-center\" data-align=\"center\">Katsetamise eesm\u00e4rk<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Carbonated soft drinks<\/td><td class=\"has-text-align-center\" data-align=\"center\">Verify carbonation consistency<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Beer<\/td><td class=\"has-text-align-center\" data-align=\"center\">Evaluate dissolved CO\u2082 content<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Sparkling water<\/td><td class=\"has-text-align-center\" data-align=\"center\">Measure carbonation level<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Energy drinks<\/td><td class=\"has-text-align-center\" data-align=\"center\">Control carbonation specifications<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Fermented beverages<\/td><td class=\"has-text-align-center\" data-align=\"center\">Analyze CO\u2082 retention<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">It can be used with different bottle formats, including glass bottles, PET bottles, and other sealed beverage containers.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Manual vs Automated Carbonation Testing Equipment<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Funktsioon<\/th><th class=\"has-text-align-center\" data-align=\"center\">Manual Carbonation Tester<\/th><th class=\"has-text-align-center\" data-align=\"center\">Automated Carbonation Analyzer<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">T\u00f6\u00f6p\u00f5him\u00f5te<\/td><td class=\"has-text-align-center\" data-align=\"center\">Manual workflow<\/td><td class=\"has-text-align-center\" data-align=\"center\">Automated measurement<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Cost<\/td><td class=\"has-text-align-center\" data-align=\"center\">Lower investment<\/td><td class=\"has-text-align-center\" data-align=\"center\">Higher investment<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Maintenance<\/td><td class=\"has-text-align-center\" data-align=\"center\">Simple maintenance<\/td><td class=\"has-text-align-center\" data-align=\"center\">More complex<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Taotlus<\/td><td class=\"has-text-align-center\" data-align=\"center\">QA labs, R&amp;D, small production<\/td><td class=\"has-text-align-center\" data-align=\"center\">High-throughput production<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Flexibility<\/td><td class=\"has-text-align-center\" data-align=\"center\">Operator-controlled testing<\/td><td class=\"has-text-align-center\" data-align=\"center\">Automated data processing<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">For laboratories that require dependable carbonation measurement with practical operation, manual systems provide an effective balance between performance and cost.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Related Standards for Carbonation Testing<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The main standards related to carbonation measurement include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/store.astm.org\/f1115-16r23.html\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">ASTM F1115<\/a> \u2013 Standard Test Method for Determining the CO\u2082 Loss of Beverage Containers<\/li>\n\n\n\n<li>GB\/T 10792 \u2013 Chinese Standard for Carbonated Beverages<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">These standards provide reference methods for evaluating carbonation characteristics and beverage container performance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why Choose CLRT-02 for Beverage CO\u2082 Testing?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The CLRT-02 Manual Carbonation Tester combines accuracy, durability, and operational simplicity for professional beverage testing applications. Its precision pressure measurement system, robust piercing structure, and manual testing workflow make it suitable for laboratories requiring reliable carbonation analysis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For beverage manufacturers, quality inspection organizations, and research laboratories, the instrument provides valuable data for controlling carbonation quality, evaluating packaging performance, and improving production consistency.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kokkuv\u00f5te<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Accurate carbonation measurement helps beverage manufacturers maintain product quality, optimize production processes, and evaluate CO\u2082 retention performance. Cell Instruments provides reliable carbonation testing equipment designed for beverage laboratories, R&amp;D centers, and quality control departments. Explore the CLRT-02 Manual Carbonation Tester and customized testing solutions to improve carbonation analysis efficiency and ensure consistent beverage performance.<\/p>","protected":false},"excerpt":{"rendered":"<p>The Manual Carbonation Tester provides a reliable and cost-effective solution for measuring dissolved carbon dioxide levels in beverage containers. Designed for quality control laboratories, beverage manufacturers, and R&amp;D facilities, this tester determines carbonation levels by measuring internal pressure and beverage temperature after sample preparation. By following a standard carbonation test method based on pressure-temperature relationships, [&hellip;]<\/p>","protected":false},"featured_media":1695,"parent":0,"template":"","meta":{"_acf_changed":false},"product-category":[],"class_list":["post-1691","product","type-product","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packtests.com\/et\/wp-json\/wp\/v2\/product\/1691","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packtests.com\/et\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.packtests.com\/et\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":5,"href":"https:\/\/www.packtests.com\/et\/wp-json\/wp\/v2\/product\/1691\/revisions"}],"predecessor-version":[{"id":1710,"href":"https:\/\/www.packtests.com\/et\/wp-json\/wp\/v2\/product\/1691\/revisions\/1710"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packtests.com\/et\/wp-json\/wp\/v2\/media\/1695"}],"wp:attachment":[{"href":"https:\/\/www.packtests.com\/et\/wp-json\/wp\/v2\/media?parent=1691"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packtests.com\/et\/wp-json\/wp\/v2\/product-category?post=1691"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}